The predominant measurement technique until now has been Gas Chromatography (GC) given the ability to separate individual compounds with high selectivity, albeit its slow response and high infrastructure requirements. For faster measurement requiring only a single heating value measurement, residual oxygen calorimetry is often used. The Precisive 5 gas analyzer requires no carrier-gases, no-calibration gases and offers fast-response analytics without compromising accuracy, repeatability, linearity or stability in the presence of interferences. Faster-response multi-component analysis provides significant cost-savings and efficiency gains in power-generation applications.

Hydrocarbon Composition Analyzer (Natural Gas, LNG, LPG, BOG, BioGas)

Features & Benefits



  • Fast response for real-time control & optimization
  • C1 – C5 alkane separation, CO2, & calorific value
  • Flow-through analysis without the need for carrier-gas
  • Remote, unattended continuous operation
  • Eliminates carrier gases and other consumables
  • Eliminates calibration gases and fuel gases
  • Virtually zero cross-sensitivity, high sensitivity & linearity

Applications

  • Natural gas analysis (processing, transmission, storage, distribution)
  • Heating value & Wobbe measurement
  • Power-gen (turbine, IC engine, fuel cell)
  • Alternative (biogas, syngas) fuels
  • LNG/LPG/BOG analysis
  • Alternative to Gas Chromatography

Description

The Precisive 5 Hydrocarbon Composition Analyzer is an infrared absorption based on-line monitoring system configured for measurement of alkanes: methane, ethane, propane, butanes and pentanes. A realtime optical analyzer capable of accurately separating the hydrocarbon components; which previously could only be performed by gas chromatograph (GC) analyzers.


Login or Register to download the Precisive 5 Hydrocarbon Composition Analyzer Datasheet

Using a unique wavelength-sweeping tunable filter spectrometer, fast update rates down to sub-second intervals are performed for the full C1 through C5 analysis. Sampling is a flow-through type, suitable for a continuous, on-line, unattended operation. The analyzer does not require carrier gas, fuel gases, or on-site calibration gases. The standard system configuration provides measurements of up to 100% methane, 25% of ethane, 25% of propane, 10% of butanes and 5% of pentanes. Other ranges and/or additional gases are available. Contact Precisive for specific requirements, compounds and ranges.

Trace VOC Analyzer (ppb/ppm Gas Detection)

Features & Benefits



  • Real-time operation down to sub-second update rates
  • Measures multiple families of hydrocarbons and VOCs
  • Ideal for remote, unattended, continuous operations
  • Eliminates carrier gases and other consumables
  • Permanent span calibration for industrial deployment
  • Interference immunity (temperature, pressure, moisture)
  • Modbus TCP/IP communications (bi-directional)

Applications

  • Industrial gas production
  • ASU (CO, CO2, THC, Moisture)
  • Blending & drying control
  • Combustion & emissions monitoring
  • Perimeter/fence-line monitoring
  • Multi-component alternative to NDIR
  • Fast-response alternative to GC

Description

The Precisive 5 Trace VOC/Hydrocarbon Analyzer is an infrared absorption based on-line monitoring system configured for measurement of hydrocarbon and VOC gases; including alkanes, alkenes, alkynes, alcohols, aldehydes and aromatics at ppm to percent levels.


Login or Register to download the Precisive 5 Trace Hydrocarbon/VOC Analyzer Datasheet

A real-time optical analyzer capable of performing compound speciation or separation; which previously could only be performed by gas chromatograph (GC) analyzers. Using a unique wavelength-sweeping tunable filter spectrometer, fast update rates down to 1-second intervals are executed for full compound speciation and detection of the customer specific compound set. Sampling is a flow-through type, suitable for a continuous, on-line, unattended operation. The analyzer does not require carrier gas, fuel gases or on-site calibration gases.

A typical system configuration provides measurements of up to the lower explosive limit (LEL) of total hydrocarbon/VOC gas with an instrument resolution of 0.1 ppm.

Contact Precisive for specific compounds, detection limits and measurement ranges.

Precisive 1 OEM Sensor Head Module

The Precisive 1 sensor module is a high-performance sensor head suitable for OEM customer requiring versatile sensor modules to be integrated into their systems. Utilizing the TFSTM technology, they enable high-accuracy, multi-compound gas analysis in a compact and rugged package.

The sensor head consists of the spectrometer, flow cell and the light detection unit. The path length of the dual-pass flow cell can easily be customized from 1 cm to 50 cm for optimal performance without affecting the rest of the optics.

Contact us for more information about the Precisive 1.

 